Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2019-10-16-6

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 208945
DEA: 07288604
EFIS: 0700021080
COOP: 074663
DIST-CO-RTE-PM07-LA-710-6.0-9.4
Award Date09/02/2011
Closeout DateNot set
Work DescriptionGerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing.
Location DescriptionPort of Long Beach (District 7)
QA Service Level1 (Verified on 06/03/2013)

Sample Information

Sample Taken Date10/16/2019 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/21/2019
Sample typeDepartment Acceptance A brief description of the sampleA490 Bolts
The quantity of what the sample constitutes6 From where was the sample collectedJob Site
First name of sampler or witnessed byMichael Last name of sampler or witnessed byEmami
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameLeJeune Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)75073905 6214661005 140647 75067668 10508080 6214506106 262342 75070176 6214552009 277861 Nut Mfg. Lot Number(s)30581-6214661005 28846-6214661005 27185-6214506106 27807-6214552009
Washer Mfg. Lot Number(s)0115-716 D3644 114 D4851 Bolt SpecificationA490
Bolt Length(s)6" 7" 10" Nut SpecificationA563 DH
Washer SpecificationF436 FinishGeomet
Diameter/Size1.25" Bolt Mfg. Lot Number050919-4FM 041719-1CM 051519-7EM 27128-105
Rocap Test Requirement(s) Lubricant Requirements(s)

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2019-10-16-6-1ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)spaine, CT HQ - Sacramento Structural Materials Testing Laboratory10/23/2019spaine
Yes
10/29/2019A490 Wedge Tensile
2019-10-16-6-2ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)spaine, CT HQ - Sacramento Structural Materials Testing Laboratory10/23/2019spaine
Yes
10/29/2019A490 Wedge Tensile
2019-10-16-6-3ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)spaine, CT HQ - Sacramento Structural Materials Testing Laboratory10/23/2019spaine
Yes
10/29/2019A490 Wedge Tensile
2019-10-16-6-4ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)spaine, CT HQ - Sacramento Structural Materials Testing Laboratory10/23/2019spaine
Yes
10/29/2019A490 Wedge Tensile
2019-10-16-6-5ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)spaine, CT HQ - Sacramento Structural Materials Testing Laboratory10/23/2019spaine
Yes
10/29/2019A490 Wedge Tensile
2019-10-16-6-6ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)spaine, CT HQ - Sacramento Structural Materials Testing Laboratory10/23/2019spaine
Yes
10/29/2019A490 Wedge Tensile
2019-10-16-6-7ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)spaine, CT HQ - Sacramento Structural Materials Testing Laboratory10/23/2019spaine
Yes
10/29/2019Nut Proof Load
2019-10-16-6-8ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)spaine, CT HQ - Sacramento Structural Materials Testing Laboratory10/23/2019spaine
Yes
10/29/2019Nut Proof Load
2019-10-16-6-9ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory10/25/2019Steven Paine
Yes
10/29/2019
2019-10-16-6-10ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory10/25/2019Steven Paine
Yes
10/29/2019

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2019-10-16-6-1 ASTM F606-14a (Verified)
DIME Test ID: 2019-10-16-6-2 ASTM F606-14a (Verified)
DIME Test ID: 2019-10-16-6-3 ASTM F606-14a (Verified)
DIME Test ID: 2019-10-16-6-4 ASTM F606-14a (Verified)
DIME Test ID: 2019-10-16-6-5 ASTM F606-14a (Verified)
DIME Test ID: 2019-10-16-6-6 ASTM F606-14a (Verified)
DIME Test ID: 2019-10-16-6-7 ASTM F606-14a (Verified)
DIME Test ID: 2019-10-16-6-8 ASTM F606-14a (Verified)
DIME Test ID: 2019-10-16-6-9 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-10-16-6-10 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-10-16-6-11 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-10-16-6-12 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-10-16-6-13 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-10-16-6-14 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-10-16-6-15 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-10-16-6-16 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-10-16-6-17 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-10-16-6-18 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-10-16-6-19 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-10-16-6-20 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-10-16-6-21 ASTM E18-15 (Verified)
DIME Test ID: 2019-10-16-6-22 ASTM E18-15 (Verified)
DIME Test ID: 2019-10-16-6-23 ASTM E18-15 (Verified)
DIME Test ID: 2019-10-16-6-24 ASTM E18-15 (Verified)
DIME Test ID: 2019-10-16-6-25 ASTM E18-15 (Verified)
DIME Test ID: 2019-10-16-6-26 ASTM E18-15 (Verified)
DIME Test ID: 2019-10-16-6-27 ASTM E18-15 (Verified)
DIME Test ID: 2019-10-16-6-28 ASTM E18-15 (Verified)
DIME Test ID: 2019-10-16-6-29 ASTM E18-15 (Verified)
DIME Test ID: 2019-10-16-6-30 ASTM E18-15 (Verified)