Summary for Test 2019-10-15-2-1

Test performed: ASTM A370-15

Project Information

Project Identifiers
DEA: No Project
DIST-CO-RTE-PM---
Award DateNot set
Closeout Date11/01/2022
Work DescriptionSpecial project identifier for material not associated with a project
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date10/15/2019 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/21/2019
Sample typeQuality Assurance A brief description of the sampleAnchor Bolt F1554 Gr. 55
The quantity of what the sample constitutes5 From where was the sample collectedFabricator
First name of sampler or witnessed byRommoney Last name of sampler or witnessed byWu
Title of samplerAMR Telephone number of sampler9164257894
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameBlue Circle Corp Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)3090556 Nut Mfg. Lot Number(s)
Washer Mfg. Lot Number(s) Bolt SpecificationASTM F1554
Bolt Length(s)6" Nut SpecificationN/A
Washer SpecificationN/A Finish
Diameter/Size1" Bolt Mfg. Lot Number
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2019-10-15-2
DIME Test ID: 2019-10-15-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2019-10-23

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 10/22/2019
UTM: 67kip
Temperature: 72 f
NumSampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
1130905560.5050.2672199163427.6spaine

General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 10/23/2019