Summary for Test 2019-09-26-10-1

Test performed: ASTM C39-10

Project Information

Project IdentifiersProject ID: 213763
DEA: 060Q19A4
EFIS: 0613000152
DIST-CO-RTE-PM06-KER-58-R99.0/R100.3
Award Date02/04/2019
Closeout Date10/22/2021
Work DescriptionWIDEN SHOULDERS AND REPLACE BRIDGES
Location DescriptionKERN COUNTY NEAR TEHACHAPI FROM 0.5 MILE WEST TO 0.8 MILE EAST OF SAND CANYON UNDERCROSSING
QA Service Level1 (Verified on 01/09/2019)

Sample Information

Sample Taken Date09/26/2019 Sample Unique Key10
Date that the sample was received by the laboratory/organization performing the testing09/27/2019 Sample typeQuality Assurance
A brief description of the sample6x12 concrete cylinders The quantity of what the sample constitutes4
From where was the sample collectedJob Site First name of sampler or witnessed byadial
Last name of sampler or witnessed byEvans Title of samplerASR
Telephone number of sampler Laboratory sample identification994-926
Linked DIME Sample ID The fabricator/manufacturer/facility nameHOLIDAY ROCK
Transportation Laboratory (TL) Number20190926 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure nameABUTMENT1 FIVE PILES WITHIN THE FOOTING FOOTPRINT
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number3h40x004
The truck number from where the sample was collected308 The batch plant ticket number from where the sample was collected112016563
Concrete batch plantUnknown The fabricator/manufacturer designation for the samplegranite
A detailed description of where the material sample was collectedTRUCK Where the material sample would have been placed if not sampledABUTMENT1 FIVE PILES WITHIN THE FOOTING FOOTPRINT
From Lot No.Unknown Bag Lot No.Unknown

Test Details

DIME Sample ID: 2019-09-26-10
DIME Test ID: 2019-09-26-10-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2019-10-04

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: MM
Date of test: 10/03/2019
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 6.01 in
Maximum load on cylinder 1: 60680 lb
Maximum load on cylinder 2: 60910 lb
Type of fracture pattern of cylinder 1: 4
Type of fracture pattern of cylinder 2: 4
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 7 days
Cross sectional area of cylinder 1: 28.37 in^2
Cross sectional area of cylinder 2: 28.37 in^2
Compressive strength of cylinder 1: 2138.9 psi
Compressive strength of cylinder 2: 2147.0 psi
Compressive strength (to nearest 10 psi): 2140 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/4/2019 ✔