Summary for Test 2019-08-16-14-1
Test performed: AASHTO T209-12Project Information
| Project Identifiers | DEA: No Project |
|---|---|
| DIST-CO-RTE-PM | --- |
| Award Date | Not set |
| Closeout Date | 11/01/2022 |
| Work Description | Special project identifier for material not associated with a project |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 08/16/2019 | Sample Unique Key | 14 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/23/2019 |
| Sample type | Verification | A brief description of the sample | Aggregate, Loose Mix, Asphalt, LAS, RAP |
| The quantity of what the sample constitutes | One JMF Verification | From where was the sample collected | Source |
| First name of sampler or witnessed by | Tom | Last name of sampler or witnessed by | Cromwell |
| Title of sampler | MNS Consultant | Telephone number of sampler | |
| Laboratory sample identification | 19-J-045 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Papich Paso Robles | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | Unknown |
| Sublot number | Unknown | HMA Mix Number | Not set |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2019-08-16-14
DIME Test ID: 2019-08-16-14-1
Testing Lab: CT D05 - San Luis Obispo District Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2019-09-26
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Eric Atkins
Date of test: 09/24/2019
Method Performed: no data
Mass of container filled with water: 7403 grams
Mass of oven-dry sample in air for Sample 1: 1902 grams
Mass of container filled with the sample and water for Sample 1: 8528 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.447
Theoretical maximum density at 25°C (77°F): no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/26/2019 ✔