Summary for Test 2019-09-04-7-5

Test performed: CTM 553-1

Project Information

Project IdentifiersProject ID: 214029
DEA: 07301104
EFIS: 0714000009
DIST-CO-RTE-PM07-LA-60,710-710-R2.8/11.8, 24.1/25.1
Award Date06/03/2019
Closeout Date10/17/2023
Work DescriptionRoadway ex, place jointed plain concrete pavement & concrete barrieres
Location DescriptionIn Los Angeles County at avocado Heights on Route 60 from 0.5 Mile west of Route 60/710 Separation to Route 60/605 Separation AND on Route 710 from 0.5 miles south of Route 710/60 Separation to 0.5 mile north of Route 710/60 Separation.
QA Service Level1 (Verified on 06/25/2019)

Sample Information

Sample Taken Date09/04/2019 Sample Unique Key7
Date that the sample was received by the laboratory/organization performing the testing09/06/2019 Sample typeVerification
A brief description of the sampleType III Cement The quantity of what the sample constitutes15 lbs
From where was the sample collectedJob Site First name of sampler or witnessed byNA
Last name of sampler or witnessed byNA Title of sampler
Telephone number of sampler Laboratory sample identificationCM194902
Linked DIME Sample ID The fabricator/manufacturer/facility nameUnknown
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeCementitious BrandMitsubishi
MillCushenbury Type of Cementitious MaterialType II Cement

Test Details

DIME Sample ID: 2019-09-04-7
DIME Test ID: 2019-09-04-7-5
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: CTM 553-1: Method for Testing Thermal Stability of Mortar Made with Hydraulic Cement
Test Release Date: 2019-10-08

Test Results


Input Type: Measured
Tester's full name: Benjamin Lenz
Date of test: 09/12/2019
Cross-sectional area of the specimen: 4 in^2
Age at the time of test: 72 hours
Maximum load at failure of specimen 1, 23 ± 1.7°C for 48h: 3294 lbs
Maximum load at failure of specimen 2, 23 ± 1.7°C for 48h: 3464 lbs
Maximum load at failure of specimen 3, 23 ± 1.7°C for 48h: 3361 lbs
Maximum load at failure of specimen 1, 50 ± 1°C for 48h: 4058 lbs
Maximum load at failure of specimen 2, 50 ± 1°C for 48h: 3968 lbs
Maximum load at failure of specimen 3, 50 ± 1°C for 48h: 4325 lbs
Average of test specimens broken to nearest 50 kPa, 23 ± 1.7°C for 48h: 5800 kPa
Average of test specimens broken to nearest 50 kPa, 50 ± 1°C for 48h: 7100 kPa
Thermal stability ratio: 122
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/8/2019 ✔