Summary for Test 2019-05-14-10-10
Test performed: CTM 203-February 2008Project Information
| Project Identifiers | Project ID: 214341 DEA: 081J2004 EFIS: 0817000237 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD-15-R21.5/R22.0 |
| Award Date | 11/16/2021 |
| Closeout Date | 10/02/2024 |
| Work Description | EXTEND DECELARATION LANE |
| Location Description | SAN BERNARDINO COUNTY NEAR HESPERIA FROM 0.1 MILE NORTH OF ROUTE 15/138 SEPARATION TO GISH OVERHEAD |
| QA Service Level | 1 (Verified on 06/23/2021) |
Sample Information
| Sample Taken Date | 05/14/2019 | Sample Unique Key | 10 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 06/12/2019 | Sample type | Per Request |
| A brief description of the sample | Soil | The quantity of what the sample constitutes | 1 bag |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Shadi |
| Last name of sampler or witnessed by | Dweab | Title of sampler | TE |
| Telephone number of sampler | 657-328-6367 | Laboratory sample identification | 8611 |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Caltrans | |
| Transportation Laboratory (TL) Number | S-17300-3 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Unknown |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | Unknown | A detailed description of where the material sample was collected | R-19-004, I-15 SB, PM 21.5-22.0 |
| Where the material sample would have been placed if not sampled | Unknown |
Test Details
DIME Sample ID: 2019-05-14-10
DIME Test ID: 2019-05-14-10-10
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 203-February 2008: Mechanical Analysis of Soils
Test Release Date: 2019-09-20
Test Results
What size aggregate is being tested?: Fine Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Input Type: Calculated
Tester's full name: Tess Perez/Kiet Phan
Date of test: 07/17/2019
Cumulative percent passing the 3/8 in. sieve: 96 %
Cumulative percent passing the #4 sieve: 93 %
Cumulative percent passing the #8 sieve: 86 %
Cumulative percent passing the #16 sieve: 77 %
Cumulative percent passing the #30 sieve: 66 %
Cumulative percent passing the #50 sieve: 54 %
Cumulative percent passing the #100 sieve: 42 %
Cumulative percent passing the #200 sieve: 33 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/20/2019 ✔