Summary for Test 2019-08-08-6-1
Test performed: ASTM F606-14Project Information
| Project Identifiers | DEA: No Project |
|---|---|
| DIST-CO-RTE-PM | --- |
| Award Date | Not set |
| Closeout Date | 11/01/2022 |
| Work Description | Special project identifier for material not associated with a project |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 08/08/2019 | Sample Unique Key | 6 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/14/2019 | Sample type | Quality Assurance |
| A brief description of the sample | 7/8" x 20" HDG Hex Bolts | The quantity of what the sample constitutes | 5 |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Arthur |
| Last name of sampler or witnessed by | Peterson | Title of sampler | QA Inspector |
| Telephone number of sampler | 707-342-8602 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | UIS Lindon UT | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | L110-102-19 | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | NA |
|---|---|---|---|
| Heat Number(s) | 190382 | Nut Mfg. Lot Number(s) | NA |
| Washer Mfg. Lot Number(s) | NA | Bolt Specification | ASTM A449 |
| Bolt Length(s) | 20" | Nut Specification | NA |
| Washer Specification | NA | Finish | Hot Dip Galvanized |
| Diameter/Size | 7/8" | Bolt Mfg. Lot Number | 32111 |
| Rocap Test Requirement(s) | NA | Lubricant Requirements(s) | NA |
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2019-08-08-6
DIME Test ID: 2019-08-08-6-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2019-09-03
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 08/23/2019
UTM: 450kip
Temperature: 72
| Num | Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments |
|---|---|---|---|---|---|---|---|---|---|
| 1 | 1 | UNC 7/8 | 0.462 | 63850 | 63850 | 138204 | 126073 | 58246 | A449 Bolt |
General comments (publicly viewable) (Max 1000 characters): A449 Bolt
Test Graph
Source: Bluehill Data Point FileTest was verified on 9/3/2019 ✔