Summary for Test 2019-08-08-21-4
Test performed: ASME B1.2-83r01Project Information
Project Identifiers | Project ID: 213261 DEA: 071XH004 EFIS: 0718000239 |
---|---|
DIST-CO-RTE-PM | 07-LA-47-.86, 0.86, 0.86 |
Award Date | 03/20/2018 |
Closeout Date | 06/03/2020 |
Work Description | Remove and replace the two (2) long finger joint assemblies at Bents 11 and 12 and repair the elevators in both towers |
Location Description | Not set |
QA Service Level | 1 (Verified on 06/08/2018) |
Sample Information
Sample Taken Date | 08/08/2019 | Sample Unique Key | 21 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/09/2019 |
Sample type | Department Acceptance | A brief description of the sample | 7/8 - 9 x 7 A325 |
The quantity of what the sample constitutes | 110 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Jamie | Last name of sampler or witnessed by | Doe |
Title of sampler | QA Inspector | Telephone number of sampler | 916-838-4505 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | CK Johnson | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S50-018-19 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 812525R |
---|---|---|---|
Heat Number(s) | 10550960, 21807850, DL18101099 | Nut Mfg. Lot Number(s) | 406805A |
Washer Mfg. Lot Number(s) | D5899 | Bolt Specification | A325 |
Bolt Length(s) | 7" | Nut Specification | A563 |
Washer Specification | F436 | Finish | HDG |
Diameter/Size | 7/8 - 9 | Bolt Mfg. Lot Number | 812525 |
Rocap Test Requirement(s) | Yes | Lubricant Requirements(s) | Yes |
Test Details
DIME Sample ID: 2019-08-08-21
DIME Test ID: 2019-08-08-21-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Test Release Date: 2019-08-22
Test Results
Input Type: Calculated
Tester's full name: Steven Paine
Date of test: 08/21/2019
Sample No.: 1C
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: 812525
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: A325 USA LE
Size: .875 in
Bolt Length: 7 in
Gage Type: Pass
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/22/2019 ✔