Summary for Test 2019-08-08-21-1
Test performed: ASTM F606-14aProject Information
| Project Identifiers | Project ID: 213261 DEA: 071XH004 EFIS: 0718000239 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-47-.86, 0.86, 0.86 |
| Award Date | 03/20/2018 |
| Closeout Date | 06/03/2020 |
| Work Description | Remove and replace the two (2) long finger joint assemblies at Bents 11 and 12 and repair the elevators in both towers |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 06/08/2018) |
Sample Information
| Sample Taken Date | 08/08/2019 | Sample Unique Key | 21 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/09/2019 |
| Sample type | Department Acceptance | A brief description of the sample | 7/8 - 9 x 7 A325 |
| The quantity of what the sample constitutes | 110 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Jamie | Last name of sampler or witnessed by | Doe |
| Title of sampler | QA Inspector | Telephone number of sampler | 916-838-4505 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | CK Johnson | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | S50-018-19 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 812525R |
|---|---|---|---|
| Heat Number(s) | 10550960, 21807850, DL18101099 | Nut Mfg. Lot Number(s) | 406805A |
| Washer Mfg. Lot Number(s) | D5899 | Bolt Specification | A325 |
| Bolt Length(s) | 7" | Nut Specification | A563 |
| Washer Specification | F436 | Finish | HDG |
| Diameter/Size | 7/8 - 9 | Bolt Mfg. Lot Number | 812525 |
| Rocap Test Requirement(s) | Yes | Lubricant Requirements(s) | Yes |
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2019-08-08-21
DIME Test ID: 2019-08-08-21-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2019-08-22
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 08/20/2019
UTM: 450kip
Temperature: no data
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1A | 812525 | 0.8750 | 66683 | 296.62 | 10.00 | spaine |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point FileTest was verified on 8/22/2019 ✔