Summary for Test 2019-01-03-4-5

Test performed: ASTM C191-13

Project Information

Project IdentifiersProject ID: 8801
DEA: AML-CEM
EFIS: AML-CEM
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for Cementitious Materials for use in Concrete Authorized Material List (AML)
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date01/03/2019 Sample Unique Key4
Date that the sample was received by the laboratory/organization performing the testing01/03/2019 Sample typeAnnual Source Testing
A brief description of the sampleType III Cement The quantity of what the sample constitutes1 Bucket
From where was the sample collectedSource First name of sampler or witnessed byUnknown
Last name of sampler or witnessed byUnknown Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationCM185852
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameLEHIGH
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeCementitious BrandLehigh
MillCupertino Type of Cementitious MaterialType III Cement

Test Details

DIME Sample ID: 2019-01-03-4
DIME Test ID: 2019-01-03-4-5
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C191-13: Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat Needle
Test Release Date: 2021-01-07

Test Results


Input Type: Calculated
Tester's full name: Benjamin Lenz
Date of test: 05/08/2019
Type of Water Used: Type IV grade reagent water
Initial time of setting: 120 min
Final time of setting: no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/7/2021 ✔