Summary for Test 2019-02-18-21-7

Test performed: ASTM D4791-10

Project Information

Project Identifiers
DEA: No Project
DIST-CO-RTE-PM---
Award DateNot set
Closeout Date11/01/2022
Work DescriptionSpecial project identifier for material not associated with a project
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date02/18/2019 Sample Unique Key21
Date that the sample was received by the laboratory/organization performing the testing02/18/2019 Sample typePreliminary
A brief description of the sampleJMF 1/2 Cold feed The quantity of what the sample constitutesJMF
From where was the sample collectedSource First name of sampler or witnessed byCarlos
Last name of sampler or witnessed byManzo Title of samplerQC Technician
Telephone number of sampler Laboratory sample identificationTEM12SPLA
Linked DIME Sample ID The fabricator/manufacturer/facility nameSPM-Templeton
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-10-0006::AVENAL AGGREGATES
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedCold Feed
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1/2 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-02-18-21
DIME Test ID: 2019-02-18-21-7
Testing Lab: Sierra Pacific Materials
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Test Release Date: 2019-07-30

Test Results


Method A - Percentage of Flat Particles, Elongated Particles, and Flat & Elongated Particles
Method B - Flat & Elongated Particles

Method: A
Determination: By Mass
Dimensional ratio used: 1:5
Input Type: Calculated
Tester's full name: unknown
Date of test: 02/18/2019
Weighted percentage of particles (by mass) that were flat: 0 %
Weighted percentage of particles (by mass) that were elongated: 0 %
Weighted percentage of particles (by mass) that were both flat and elongated: 0 %
Weighted percentage of particles (by mass) that were neither flat nor elongated: 0 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/30/2019 ✔