Summary for Test 2019-07-16-2-1

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 3807
DEA: 07121844
EFIS: 0700000117
DIST-CO-RTE-PM07-LA-5-42.8/47.3
Award Date12/06/2010
Closeout Date06/30/2021
Work DescriptionCONSTRUCT HOV LANES, RETAINING WALLS AND SOUND WALLS.
Location DescriptionLOS ANGELES COUNTY IN LOS ANGELES, GLENDALE, AND BURBANK FROM ROUTE 5/134 SEPARATION TO MAGNOLIA BOULEVARD OVERCROSSING
QA Service Level1 (Verified on 02/23/2012)

Sample Information

Sample Taken Date07/16/2019 Sample Unique Key2
Date that the sample was received by the laboratory/organization performing the testing07/22/2019 Sample typeQuality Assurance
A brief description of the sampleA325 HDG Rocap Assembiy The quantity of what the sample constitutes65
From where was the sample collectedDistributor First name of sampler or witnessed byHitesh
Last name of sampler or witnessed byPatel Title of samplerQuality Assurance Inspector
Telephone number of sampler9168691602 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameIndustrial Bolt and Supply
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL131-152-19
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)00801
Heat Number(s)100890222 Bolt, 100894221 Nut, 31835900 washer Nut Mfg. Lot Number(s)414844C
Washer Mfg. Lot Number(s)1218-042 Bolt SpecificationA325
Bolt Length(s)2" Nut SpecificationA194-2H
Washer SpecificationF436 FinishHot Dip Galvanized
Diameter/Size1/2" Bolt Mfg. Lot Number403427A
Rocap Test Requirement(s)Yes Lubricant Requirements(s)Yes
Washer Inner Diameter(s) Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Test Details

DIME Sample ID: 2019-07-16-2
DIME Test ID: 2019-07-16-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2019-07-25

Test Results


Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Steve
Date of test: 07/23/2019
UTM: 400KIP
Temperature: no data
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
11A403427A1/2\"2014889.610A325Steve

General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point File

Test was verified on 7/25/2019 ✔