Sample Record
Owner Lab
- CT HQ - QASI Los Angeles Field Office
DIME Sample ID 2019-07-16-2
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 3807 DEA: 07121844 EFIS: 0700000117 |
---|---|
DIST-CO-RTE-PM | 07-LA-5-42.8/47.3 |
Award Date | 12/06/2010 |
Closeout Date | 06/30/2021 |
Work Description | CONSTRUCT HOV LANES, RETAINING WALLS AND SOUND WALLS. |
Location Description | LOS ANGELES COUNTY IN LOS ANGELES, GLENDALE, AND BURBANK FROM ROUTE 5/134 SEPARATION TO MAGNOLIA BOULEVARD OVERCROSSING |
QA Service Level | 1 (Verified on 02/23/2012) |
Sample Information
Sample Taken Date | 07/16/2019 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/22/2019 |
Sample type | Quality Assurance | A brief description of the sample | A325 HDG Rocap Assembiy |
The quantity of what the sample constitutes | 65 | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Hitesh | Last name of sampler or witnessed by | Patel |
Title of sampler | Quality Assurance Inspector | Telephone number of sampler | 9168691602 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Industrial Bolt and Supply | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L131-152-19 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 00801 |
---|---|---|---|
Heat Number(s) | 100890222 Bolt, 100894221 Nut, 31835900 washer | Nut Mfg. Lot Number(s) | 414844C |
Washer Mfg. Lot Number(s) | 1218-042 | Bolt Specification | A325 |
Bolt Length(s) | 2" | Nut Specification | A194-2H |
Washer Specification | F436 | Finish | Hot Dip Galvanized |
Diameter/Size | 1/2" | Bolt Mfg. Lot Number | 403427A |
Rocap Test Requirement(s) | Yes | Lubricant Requirements(s) | Yes |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2019-07-16-2-1 ASTM F606-14a (Verified)
DIME Test ID: 2019-07-16-2-2 ASTM F606-14a (Verified)
DIME Test ID: 2019-07-16-2-3 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-07-16-2-4 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-07-16-2-5 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-07-16-2-6 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-07-16-2-7 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-07-16-2-8 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-07-16-2-9 ASTM B499-14 (Verified)
DIME Test ID: 2019-07-16-2-10 ASTM B499-14 (Verified)
DIME Test ID: 2019-07-16-2-11 ASTM B499-14 (Verified)
DIME Test ID: 2019-07-16-2-12 ASTM B499-14 (Verified)
DIME Test ID: 2019-07-16-2-13 ASTM B499-14 (Verified)
DIME Test ID: 2019-07-16-2-14 ASTM B499-14 (Verified)
DIME Test ID: 2019-07-16-2-15 ASTM B499-14 (Verified)
DIME Test ID: 2019-07-16-2-16 ASTM B499-14 (Verified)
DIME Test ID: 2019-07-16-2-17 ASTM B499-14 (Verified)
DIME Test ID: 2019-07-16-2-18 ASTM E18-15 (Verified)
DIME Test ID: 2019-07-16-2-19 ASTM E18-15 (Verified)