Summary for Test 2019-07-02-18-1
Test performed: ASTM F606-14aProject Information
| Project Identifiers | DEA: No Project |
|---|---|
| DIST-CO-RTE-PM | --- |
| Award Date | Not set |
| Closeout Date | 11/01/2022 |
| Work Description | Special project identifier for material not associated with a project |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 07/02/2019 | Sample Unique Key | 18 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/09/2019 | Sample type | Quality Assurance |
| A brief description of the sample | 1" x 5" A325 Bolts MG | The quantity of what the sample constitutes | 12 |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Arthur |
| Last name of sampler or witnessed by | Peterson | Title of sampler | QA Inspector |
| Telephone number of sampler | 707-342-8602 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | UIS | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | L110-087-19 | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | TT0115560 |
|---|---|---|---|
| Heat Number(s) | 10541280 | Nut Mfg. Lot Number(s) | |
| Washer Mfg. Lot Number(s) | Bolt Specification | A325 | |
| Bolt Length(s) | 5" | Nut Specification | NA |
| Washer Specification | NA | Finish | MG |
| Diameter/Size | 1" x 5" | Bolt Mfg. Lot Number | BM0742 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2019-07-02-18
DIME Test ID: 2019-07-02-18-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2019-07-23
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Steve
Date of test: 07/15/2019
UTM: 400KIP
Temperature: no data
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1A | BM0742 | 1\" | 88164 | 392.2 | 10 | A325 | Steve |
General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point FileTest was verified on 7/23/2019 ✔