Summary for Test 2019-06-06-1-8
Test performed: ASTM B499-14Project Information
Project Identifiers | DEA: No Project |
---|---|
DIST-CO-RTE-PM | --- |
Award Date | Not set |
Closeout Date | 11/01/2022 |
Work Description | Special project identifier for material not associated with a project |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 06/06/2019 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/18/2019 |
Sample type | Quality Assurance | A brief description of the sample | 2-1/2" X 5' 0" F1554 gr.55 Anchor Rods HDG/Plain |
The quantity of what the sample constitutes | 576 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Joe | Last name of sampler or witnessed by | Adame |
Title of sampler | CT METS QA INSPECTOR | Telephone number of sampler | 3609531155 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Universal Industrial Sales | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B53-055-19 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | N/A |
---|---|---|---|
Heat Number(s) | 1201010574 | Nut Mfg. Lot Number(s) | N/A |
Washer Mfg. Lot Number(s) | N/A | Bolt Specification | F1554 gr.55 |
Bolt Length(s) | 5' 0" | Nut Specification | N/A |
Washer Specification | N/A | Finish | HDG/Plain |
Diameter/Size | 2-1/2" | Bolt Mfg. Lot Number | 1201057420 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2019-06-06-1
DIME Test ID: 2019-06-06-1-8
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2019-06-21
Test Results
Input Type: Calculated
Tester's full name: Brian Ewing
Date of test: 06/21/2019
Sample No.: 1A
Rocap Number: no data
Heat Number(s): 1201010574
Mfg. Lot Number: no data
Finish Coating: Plain and ASTM F2329 - Hot Dip
Product Markings: YELLOW PAINT
Size: 2.5 in
Bolt Length: 60 in
Measurement Average: 7.58 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/21/2019 ✔