Summary for Test 2019-05-20-26-4

Test performed: ASTM A931-0810

Project Information

Project Identifiers
DEA: No Project
DIST-CO-RTE-PM---
Award DateNot set
Closeout Date11/01/2022
Work DescriptionSpecial project identifier for material not associated with a project
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date05/20/2019 Sample Unique Key26
Date that the sample was received by the laboratory/organization performing the testing05/20/2019 Sample typeDepartment Acceptance
A brief description of the sampleWire Rope The quantity of what the sample constitutes1
From where was the sample collectedOther First name of sampler or witnessed byTapajr
Last name of sampler or witnessed byHector Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility name04 Toll Bridge Paint Crew
Transportation Laboratory (TL) NumberNA Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM10 - Wire Rope Choker Reel Number1
Painter Name or IDHector, Carlos, Albert Material SpecificationASTM A931
Size5/16 in Wire ManufacturerCable More
Material Collected to TestOperator

Test Details

DIME Sample ID: 2019-05-20-26
DIME Test ID: 2019-05-20-26-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Test Release Date: 2019-06-12

Test Results


Input Type: Calculated
Tester's full name: Brian
Date of test: 06/05/2019
Temperature: 72 F
UTM: 67 KIP
Specimen Identification: Wire Rope
Peak Load: 8955 lbf
Operator: S144256
Location of Failure: Clamp
General comments (publicly viewable) (Max 1000 characters): Cable Pulled Out of Clamp
Test Graph
Source: Partner Data Point File
Test graph for 2019-05-20-26-4

Test was verified on 6/5/2019 ✔