Summary for Test 2019-05-13-5-3
Test performed: ASTM D624-00-re12Project Information
| Project Identifiers | Project ID: 213763 DEA: 060Q19A4 EFIS: 0613000152 |
|---|---|
| DIST-CO-RTE-PM | 06-KER-58-R99.0/R100.3 |
| Award Date | 02/04/2019 |
| Closeout Date | 10/22/2021 |
| Work Description | WIDEN SHOULDERS AND REPLACE BRIDGES |
| Location Description | KERN COUNTY NEAR TEHACHAPI FROM 0.5 MILE WEST TO 0.8 MILE EAST OF SAND CANYON UNDERCROSSING |
| QA Service Level | 1 (Verified on 01/09/2019) |
Sample Information
| Sample Taken Date | 05/13/2019 | Sample Unique Key | 5 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 05/20/2019 | Sample type | Quality Assurance |
| A brief description of the sample | Bearing Pad | The quantity of what the sample constitutes | 1 |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Kayla |
| Last name of sampler or witnessed by | Wallace | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Dynamic Rubber | |
| Transportation Laboratory (TL) Number | NA | Inspector Lot Number from the Transportation Laboratory (TL) Form | NA |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM1 - Elastomeric Bearing Pad | Mfg. Lot Number(s) | CR55-003-19 |
|---|---|---|---|
| Material/Compound/Elastomer ID | NA | Samples Representing | Unknown |
| Description (size) | 2.30" x 12" x 20" | Comments | Unknown |
| Description (Number of Shims) | 4 | Type of Bearing Pad | Steel |
| Description (Thickness of Shims) | 14 gage | Manufacturer(s) | Dynamic Rubber |
| Batch Number | NA |
Test Details
DIME Sample ID: 2019-05-13-5
DIME Test ID: 2019-05-13-5-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Test Release Date: 2019-06-07
Test Results
Number of specimens tested: 3
Input Type: Measured
Tester's full name: Brian
Date of test: 05/22/2019
Humidity: 50 %
Temperature: 72 F
Sample 1 Median Thickness: 0.061 in
Sample 1 Tear Strength: 180.3 lbf / in
Sample 2 Median Thickness: 0.063 in
Sample 2 Tear Strength: 190.5 lbf / in
Sample 3 Median Thickness: 0.06 in
Sample 3 Tear Strength: 183.3 lbf / in
UTM: no data
Median of the Tear Strength Values: 183.3 lb/in
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for Sample 1
Source: Partner Data Point File
Test graph for Sample 2
Source: Partner Data Point File
Test graph for Sample 3
Test was verified on 5/31/2019 ✔