Summary for Test 2019-05-08-7-3
Test performed: ASTM F606-14aProject Information
| Project Identifiers | DEA: No Project |
|---|---|
| DIST-CO-RTE-PM | --- |
| Award Date | Not set |
| Closeout Date | 11/01/2022 |
| Work Description | Special project identifier for material not associated with a project |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 05/08/2019 | Sample Unique Key | 7 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 05/14/2019 | Sample type | Quality Assurance |
| A brief description of the sample | F1554 Grade 105 HDG Anchor Bolts | The quantity of what the sample constitutes | 1209 |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Hitesh |
| Last name of sampler or witnessed by | Patel | Title of sampler | Quality Assurance Inspector |
| Telephone number of sampler | 9168691602 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Blue Circle Corp | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | L131-085-19 | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | n/a |
|---|---|---|---|
| Heat Number(s) | Anchor Bolts 188799 Nuts 6214785803 Washers 41808110 | Nut Mfg. Lot Number(s) | 30249 |
| Washer Mfg. Lot Number(s) | D5958 | Bolt Specification | F1554 |
| Bolt Length(s) | 40" | Nut Specification | A563-DH |
| Washer Specification | F436 | Finish | HDG |
| Diameter/Size | 1" | Bolt Mfg. Lot Number | 188799 |
| Rocap Test Requirement(s) | no | Lubricant Requirements(s) | |
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2019-05-08-7
DIME Test ID: 2019-05-08-7-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2019-06-06
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Steve
Date of test: 05/20/2019
UTM: 400KIP
Temperature: 72 F
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 1A | 30249 | 1\" | 93775 | 417.13 | Nut Proof Load | Steve |
General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Partner Data Point FileTest was verified on 5/30/2019 ✔