Summary for Test 2019-04-24-1-1

Test performed: ASTM F606-14a

Project Information

Project Identifiers
DEA: No Project
DIST-CO-RTE-PM---
Award DateNot set
Closeout Date11/01/2022
Work DescriptionSpecial project identifier for material not associated with a project
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date04/24/2019 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing04/26/2019 Sample typeVerification
A brief description of the sample3/4" x 5 1/2" A325 HDG bolt The quantity of what the sample constitutes9
From where was the sample collectedFabricator First name of sampler or witnessed byDavid
Last name of sampler or witnessed byFlygare Title of samplerCT METS QA INSPECTOR
Telephone number of sampler8016692984 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameUIS
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormB76-059-19
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)none
Heat Number(s)10553020 Nut Mfg. Lot Number(s)n/a
Washer Mfg. Lot Number(s)n/a Bolt SpecificationA325
Bolt Length(s)5 1/2" Nut Specificationn/a
Washer Specificationn/a FinishHDG
Diameter/Size3/4" Bolt Mfg. Lot NumberSLSB-G9534
Rocap Test Requirement(s)none Lubricant Requirements(s)none
Washer Inner Diameter(s) Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Test Details

DIME Sample ID: 2019-04-24-1
DIME Test ID: 2019-04-24-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2019-05-14

Test Results


Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 05/03/2019
UTM: 400KIP
Temperature: no data
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
11AG95343/4\"51811230.510A325Brian

General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point File