Summary for Test 2019-04-16-12-5

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 211772
DEA: 043G4624
EFIS: 0412000062
DIST-CO-RTE-PM04-CC-680-25.0-25.4
Award Date01/04/2017
Closeout Date11/12/2019
Work DescriptionFloor Beam Mitigation at Benicia-Martinez Bridge (28-0153L)
Location DescriptionBenicia-Martinez Bridge Floor Beam Mitigation Project
QA Service Level1 (Verified on 09/23/2016)

Sample Information

Sample Taken Date04/16/2019 Sample Unique Key12
Date that the sample was received by the laboratory/organization performing the testing04/16/2019 Sample typeQuality Assurance
A brief description of the sampleA325 Fasteners The quantity of what the sample constitutesas per sampling table
From where was the sample collectedFabricator First name of sampler or witnessed byRichard
Last name of sampler or witnessed byBettencourt Title of samplerQA Inspector
Telephone number of sampler209-201-5432 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCK Johnson Industries
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormS25-064-19
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)R407066A-2, R350831A, R33459A, R382642A, R332919A, R321531A, R282789A,
Heat Number(s)100888940, NF14102452, NF13203760, NF16103168, NF13202676, NF12204477, NF10103192, DL17102697, DL15107150 Nut Mfg. Lot Number(s)363695A,36395A,36395A, 36395A, 374243A, 374243A, 374243A,
Washer Mfg. Lot Number(s)C9199M, C9199M, C9199M, C9199M, 0917-628, 0917-628, 0917-628, Bolt SpecificationA325
Bolt Length(s)3",3-3/4",4-1/4",4-3/4",4-1/2" , 5-1/2", 6", Nut SpecificationDH MG
Washer SpecificationF436, FinishMech Galv
Diameter/Size1", 1", 1", 1", 7/8", 7/8", 7/8" Bolt Mfg. Lot Number406066A, 350831A, 33459A, 382642A, 33291A, 32
Rocap Test Requirement(s) Lubricant Requirements(s)
Washer Inner Diameter(s) Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Test Details

DIME Sample ID: 2019-04-16-12
DIME Test ID: 2019-04-16-12-5
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2019-05-08

Test Results


Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Steve
Date of test: 04/30/2019
UTM: 400KIP
Temperature: no data
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
15A332919A7/8\"67105298.510A325Steve

General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point File

Test was verified on 5/1/2019 ✔