Summary for Test 2019-03-27-1-3
Test performed: ASTM F606-14aProject Information
Project Identifiers | DEA: No Project |
---|---|
DIST-CO-RTE-PM | --- |
Award Date | Not set |
Closeout Date | 11/01/2022 |
Work Description | Special project identifier for material not associated with a project |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 03/27/2019 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/27/2019 |
Sample type | Quality Assurance | A brief description of the sample | ASTM F1554 Gr 55 Anchor Bolt with nut and washer |
The quantity of what the sample constitutes | 48 Bolts | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | David | Last name of sampler or witnessed by | Weeks |
Title of sampler | Associate Steel Inspector | Telephone number of sampler | 310-883-8369 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | AM Nut and Bolt | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L79-133-19 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | NA |
---|---|---|---|
Heat Number(s) | 58036769-04 | Nut Mfg. Lot Number(s) | 28099-178003 |
Washer Mfg. Lot Number(s) | 304172 | Bolt Specification | F1554 Gr 55 |
Bolt Length(s) | 18" | Nut Specification | A563 |
Washer Specification | F436 | Finish | Galvanized |
Diameter/Size | 3/4 | Bolt Mfg. Lot Number | 45577-PPO |
Rocap Test Requirement(s) | NA | Lubricant Requirements(s) | NA |
Test Details
DIME Sample ID: 2019-03-27-1
DIME Test ID: 2019-03-27-1-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2019-05-03
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 04/16/2019
UTM: 400KIP
Temperature: 72 F
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 1A | 28099-178003 | ?\" | 50719 | 225.61 | Nut Proof Load | Fred |
General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Partner Data Point FileTest was verified on 4/26/2019 ✔