Summary for Test 2019-01-10-6-2
Test performed: AASHTO T316-17Project Information
Project Identifiers | Project ID: 7613 DEA: 071218W4 EFIS: 0700021119 |
---|---|
DIST-CO-RTE-PM | 07-LA-5-29.4/31.6 |
Award Date | 11/29/2012 |
Closeout Date | 07/31/2023 |
Work Description | REALIGN ROUTE 5 AND RAILROAD TRACKS AND RECONFIGURE ON- AND OFF-RAMPS. |
Location Description | LOS ANGELES COUNTY IN BURBANK FROM WEST MAGNOLIA BOULEVARD OVERCROSSING TO 0.3 MILE NORTH OF BUENA VISTA STREET/WINONA AVENUE UNDERCROSSING |
QA Service Level | 1 (Verified on 10/08/2012) |
Sample Information
Sample Taken Date | 01/10/2019 | Sample Unique Key | 6 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/16/2019 |
Sample type | Verification | A brief description of the sample | Vulcan Sun Valley |
The quantity of what the sample constitutes | 4QT can | From where was the sample collected | Job Site |
First name of sampler or witnessed by | NA | Last name of sampler or witnessed by | NA |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 0107A-19 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Vulcan Sun Valley | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
Structure name | Not set |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 64-10/16 |
---|---|---|---|
Modified | No | Lot number | Not set |
Sublot number | Not set | Tank number | Not set |
Time of sample | Not set | HMA Supplier | Not set |
Certified Asphalt Supplier | Not set | Multigrade | Not set |
Multigrade Type | Not set | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2019-01-10-6
DIME Test ID: 2019-01-10-6-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T316-17: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2019-05-15
Test Results
Is viscosity reading in cP/Pa-s?: Pa-s
Input Type: Calculated
Tester's full name: Donya Heidari
Date of test: 01/22/2019
Time of test: 6:40 HH:MM
Test Temperature: 135 C
Speed: 50 rpm
Spindle size: 21 in
Torque: 35 %
Viscosity reading #1 (A) : 0.347 Pa-s
Viscosity reading #2 (B) : 0.353 Pa-s
Viscosity reading #3 (C): 0.354 Pa-s
Average viscosity: 0.354 Pa-s
General comments (publicly viewable) (Max 1000 characters): The tester ignored viscosity reading for 0.347
Test was verified on 5/8/2019 ✔