Summary for Test 2019-03-26-3-1

Test performed: AASHTO T27-14

Project Information

Project Identifiers
DEA: No Project
DIST-CO-RTE-PM---
Award DateNot set
Closeout Date11/01/2022
Work DescriptionSpecial project identifier for material not associated with a project
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date03/26/2019 Sample Unique Key3
Date that the sample was received by the laboratory/organization performing the testing03/26/2019 Sample typeQuality Control
A brief description of the samplecoarse aggregate The quantity of what the sample constitutes1000 tons
From where was the sample collectedSource First name of sampler or witnessed bybrett
Last name of sampler or witnessed bysoldano Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameTeichert Matls Vernalis
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-37-0037::BORDER HIGHLANDS PIT
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedStockpile
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1/2 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-03-26-3
DIME Test ID: 2019-03-26-3-1
Testing Lab: CT HQ - Sacramento Materials Management Branch Field Office
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2019-03-26

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): Yes
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: Brett Soldano
Date of test: 03/26/2019
Cumulative Percent Passing
%
100 %
100 %
100 %
93 %
43 %
9 %
4 %
0 %
0 %
0 %
0 %
0 %
0 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/26/2019 ✔