Summary for Test 2019-02-22-3-3
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 213470 DEA: 06394604 EFIS: 0600020595 |
---|---|
DIST-CO-RTE-PM | 06-FRE-269-10.6/12.4 |
Award Date | 11/02/2018 |
Closeout Date | 10/15/2020 |
Work Description | REPLACE BRIDGES AND RECONSTRUCT ROADWAY. |
Location Description | FRESNO COUNTY NEAR HURON FROM 1.0 MILE NORTH OF PALMER AVENUE TO 0.4 MILE SOUTH OF ROUTE 198 |
QA Service Level | 1 (Verified on 09/25/2018) |
Sample Information
Sample Taken Date | 02/22/2019 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/22/2019 |
Sample type | Quality Assurance | A brief description of the sample | UBS Hoops |
The quantity of what the sample constitutes | 150 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Ken | Last name of sampler or witnessed by | Varela |
Title of sampler | Telephone number of sampler | (562) 440-7716 | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | TNT Rebar | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L08-017-19 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Rebar Heat Number(s) | 4083637 |
Hoop Manufacturer Lot Number(s) | 3 | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | 5 |
Diameter of Hoop | 1'-4" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | CMC Steel |
Welding Company | TNT Rebar | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2019-02-22-3
DIME Test ID: 2019-02-22-3-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2019-03-11
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 03/01/2019
UTM: 400KIP
Temperature: 72 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 3 | 3 | #5/16mm | 0.31 | 30300 | 97740 | Bar Broke at Weld | Brian |
General comments (publicly viewable) (Max 1000 characters): Bar Broke at Weld
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 3/4/2019 ✔