Summary for Test 2019-02-14-3-7
Test performed: ASTM B499-14Project Information
| Project Identifiers | DEA: No Project |
|---|---|
| DIST-CO-RTE-PM | --- |
| Award Date | Not set |
| Closeout Date | 11/01/2022 |
| Work Description | Special project identifier for material not associated with a project |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 02/14/2019 | Sample Unique Key | 3 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 02/21/2019 | Sample type | Quality Assurance |
| A brief description of the sample | F3125 GR A325 MG Hex Bolt | The quantity of what the sample constitutes | 1 lot of 21 |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Russell |
| Last name of sampler or witnessed by | Lynch | Title of sampler | |
| Telephone number of sampler | 3609216934 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | UIS Lindon UT | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | L96-046-19 | |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | NF1520135352 | Nut Mfg. Lot Number(s) | M4342 |
| Washer Mfg. Lot Number(s) | Bolt Specification | F3125/A325/A153/B695 | |
| Bolt Length(s) | 4-1/2" | Nut Specification | N/A |
| Washer Specification | N/A | Finish | MG |
| Diameter/Size | 1-1/2" | Bolt Mfg. Lot Number | |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2019-02-14-3
DIME Test ID: 2019-02-14-3-7
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2019-03-11
Test Results
Input Type: Calculated
Tester's full name: Steven Paine
Date of test: 02/27/2019
Sample No.: 1C
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: M4342
Finish Coating: ASTM B695 - Mech Galv
Product Markings: A325 UNY USA
Size: 1.5 in
Bolt Length: 4.5 in
Measurement Average: 5.91 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/4/2019 ✔