Summary for Test 2019-02-13-2-2
Test performed: ASTM A370-15Project Information
Project Identifiers | DEA: No Project |
---|---|
DIST-CO-RTE-PM | --- |
Award Date | Not set |
Closeout Date | 11/01/2022 |
Work Description | Special project identifier for material not associated with a project |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 02/13/2019 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/21/2019 |
Sample type | Quality Assurance | A brief description of the sample | F1554 Anchor Bolt Assembly |
The quantity of what the sample constitutes | 152 | From where was the sample collected | Source |
First name of sampler or witnessed by | Prakash | Last name of sampler or witnessed by | Patel |
Title of sampler | TET II | Telephone number of sampler | 562 665-4686 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | AMNB | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L11-001-19 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | N/A |
---|---|---|---|
Heat Number(s) | 3081115, 2978475075703, 312545 | Nut Mfg. Lot Number(s) | |
Washer Mfg. Lot Number(s) | Bolt Specification | F1554 | |
Bolt Length(s) | Unknown | Nut Specification | A194 |
Washer Specification | F436 | Finish | Galv |
Diameter/Size | 1-1/4" x 36" | Bolt Mfg. Lot Number | |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2019-02-13-2
DIME Test ID: 2019-02-13-2-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2019-03-11
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Steve
Date of test: 02/25/2019
UTM: 67KIP
Temperature: 72 f
Num | Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 2 | 3081115 | 0.498 | 0.195 | 67456 | 91000 | 26.7 | Steve |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 3/4/2019 ✔