Summary for Test 2019-02-11-2-5
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 213442 DEA: 112E1504 EFIS: 1117000179 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-5-38.1/39.3 |
| Award Date | 11/06/2017 |
| Closeout Date | 09/20/2021 |
| Work Description | (ALTERNATIVE DELIVERY) WETLAND CONSTRUCTION |
| Location Description | NEAR STATE HIGHWAY IN SAN DIEGO COUNTY IN SOLANA BEACH AND ENCINITAS AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 08/28/2018) |
Sample Information
| Sample Taken Date | 02/11/2019 | Sample Unique Key | 2 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 02/13/2019 | Sample type | Quality Assurance |
| A brief description of the sample | #6 Flash Welded Hoops | The quantity of what the sample constitutes | 230 |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Arthur |
| Last name of sampler or witnessed by | Peterson | Title of sampler | CT METS QA INSPECTOR |
| Telephone number of sampler | 707-342-8602 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | CMC Rebar | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | L110 017-19 | |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | 4082089 |
| Hoop Manufacturer Lot Number(s) | Lot 1 and Lot 2 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | 6 |
| Diameter of Hoop | 2'-10" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | CMC Rebar |
| Welding Company | CMC Rebar (Etiwanda) | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2019-02-11-2
DIME Test ID: 2019-02-11-2-5
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2019-02-26
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 02/19/2019
UTM: 400KIP
Temperature: 72 F
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 2 | 2 | #6/19mm | 0.44 | 39380 | 89500 | Bar Broke | Fred |
General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 2/19/2019 ✔