Summary for Test 2019-02-06-8-1
Test performed: ASTM A370-15Project Information
| Project Identifiers | DEA: No Project |
|---|---|
| DIST-CO-RTE-PM | --- |
| Award Date | Not set |
| Closeout Date | 11/01/2022 |
| Work Description | Special project identifier for material not associated with a project |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 02/06/2019 | Sample Unique Key | 8 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/11/2019 |
| Sample type | Quality Assurance | A brief description of the sample | F1554 Grade 55 HDG Anchor Bolts |
| The quantity of what the sample constitutes | 614 pieces | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Hitesh | Last name of sampler or witnessed by | Patel |
| Title of sampler | Quality Assurance Inspector | Telephone number of sampler | 7142519350 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Blue Circle Corp | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L131-013-19 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | n/a |
|---|---|---|---|
| Heat Number(s) | 1201001787 | Nut Mfg. Lot Number(s) | n/a |
| Washer Mfg. Lot Number(s) | n/a | Bolt Specification | F1554 |
| Bolt Length(s) | 42" | Nut Specification | n/a |
| Washer Specification | n/a | Finish | HDG |
| Diameter/Size | 2 1/4" | Bolt Mfg. Lot Number | n/a |
| Rocap Test Requirement(s) | no | Lubricant Requirements(s) | |
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2019-02-06-8
DIME Test ID: 2019-02-06-8-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2019-02-21
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Steve
Date of test: 02/14/2019
UTM: 67KIP
Temperature: 72 f
| Num | Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1 | 1201001787 | 0.501 | 0.197 | 62518 | 85770 | 27.1 | Steve |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 2/14/2019 ✔