Summary for Test 2018-12-28-3-1
Test performed: ASTM F606-14aProject Information
| Project Identifiers | Project ID: 208945 DEA: 07288604 EFIS: 0700021080 COOP: 074663 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-710-6.0-9.4 |
| Award Date | 09/02/2011 |
| Closeout Date | Not set |
| Work Description | Gerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing. |
| Location Description | Port of Long Beach (District 7) |
| QA Service Level | 1 (Verified on 06/03/2013) |
Sample Information
| Sample Taken Date | 12/28/2018 | Sample Unique Key | 3 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/17/2019 |
| Sample type | Independent Assurance | A brief description of the sample | F3125 GR A325 Fastener Assembly |
| The quantity of what the sample constitutes | 600 | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | William | Last name of sampler or witnessed by | Clifford |
| Title of sampler | INDEPENDENT QA | Telephone number of sampler | 5103253065 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Nucor | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L78-060-18 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | L1413003, L1413004 |
|---|---|---|---|
| Heat Number(s) | 412553BZ | Nut Mfg. Lot Number(s) | TN731 |
| Washer Mfg. Lot Number(s) | D4996Z, D6240 | Bolt Specification | F3125 |
| Bolt Length(s) | 3" | Nut Specification | A563 DH |
| Washer Specification | F436 | Finish | Mech Galv |
| Diameter/Size | 1" | Bolt Mfg. Lot Number | 412553BZ |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2018-12-28-3
DIME Test ID: 2018-12-28-3-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2019-01-30
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 01/23/2019
UTM: 400KIP
Temperature: no data
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1A | 412553BZ | 1\" | 87834 | 390.7 | 10 | A325 | Fred |
General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point FileTest was verified on 1/23/2019 ✔