Summary for Test 2019-01-14-4-1

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 212888
DEA: 07202124
EFIS: 0700020870
DIST-CO-RTE-PM07-LA-710-20.9/24.6
Award Date02/16/2018
Closeout Date05/04/2022
Work DescriptionPAVEMENT REHABILITATION AND BRIDGE WIDENING
Location DescriptionLOS ANGELES COUNTY IN AND NEAR BELL, VERNON, AND CITY OF COMMERCE, FROM 0.2 MILE SOUTH OF SLAUSON AVENUE OVERCROSSING TO 0.1 MILE NORTH OF THIRD STREET OVERCROSSING
QA Service Level1 (Verified on 03/29/2018)

Sample Information

Sample Taken Date01/14/2019 Sample Unique Key4
Date that the sample was received by the laboratory/organization performing the testing01/14/2019 Sample typeQuality Assurance
A brief description of the sampleHRC 500/510 The quantity of what the sample constitutes256 Bars
From where was the sample collectedFabricator First name of sampler or witnessed byDavid
Last name of sampler or witnessed byWeeks Title of samplerQA
Telephone number of sampler310-883-8369 Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameCMC Etiwanda
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormL79-001-19
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerGerdau
Coupler ManufacturerHRC Intermediate Assembler or FabricatorCMC Rebar Etiwanda
Rebar Size14 Coupler ModelHRC 500 /510 XTender
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterNA Rebar Hoop FabricatorNA
Coupler Component Heat/Lot Number(s)A162884 / 73101431 Rebar Heat Number(s)6502943903
Rebar Size 2 Coupler Unique IDNot set

Test Details

DIME Sample ID: 2019-01-14-4
DIME Test ID: 2019-01-14-4-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2019-01-25

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 01/18/2019
UTM: 2000KIP
Halo ID: Big
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
111#14/43mm2.25-0.0056228539101570necking okayBrian

General comments (publicly viewable) (Max 1000 characters): necking okay
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 1/18/2019 ✔