Sample Record

Owner Lab

  • CT HQ - QASI Los Angeles Field Office

DIME Sample ID 2019-01-14-4

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 212888
DEA: 07202124
EFIS: 0700020870
DIST-CO-RTE-PM07-LA-710-20.9/24.6
Award Date02/16/2018
Closeout Date05/04/2022
Work DescriptionPAVEMENT REHABILITATION AND BRIDGE WIDENING
Location DescriptionLOS ANGELES COUNTY IN AND NEAR BELL, VERNON, AND CITY OF COMMERCE, FROM 0.2 MILE SOUTH OF SLAUSON AVENUE OVERCROSSING TO 0.1 MILE NORTH OF THIRD STREET OVERCROSSING
QA Service Level1 (Verified on 03/29/2018)

Sample Information

Sample Taken Date01/14/2019 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/14/2019
Sample typeQuality Assurance A brief description of the sampleHRC 500/510
The quantity of what the sample constitutes256 Bars From where was the sample collectedFabricator
First name of sampler or witnessed byDavid Last name of sampler or witnessed byWeeks
Title of samplerQA Telephone number of sampler310-883-8369
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameCMC Etiwanda Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormL79-001-19 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerGerdau
Coupler ManufacturerHRC Intermediate Assembler or FabricatorCMC Rebar Etiwanda
Rebar Size14 Coupler ModelHRC 500 /510 XTender
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterNA Rebar Hoop FabricatorNA
Coupler Component Heat/Lot Number(s)A162884 / 73101431 Rebar Heat Number(s)6502943903
Rebar Size 2 Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2019-01-14-4-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory01/18/2019Brian
Yes
01/25/2019necking okay
2019-01-14-4-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory01/18/2019Brian
Yes
01/25/2019necking okay
2019-01-14-4-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory01/18/2019Brian
Yes
01/25/2019necking okay
2019-01-14-4-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory01/18/2019Brian
Yes
01/25/2019necking okay
2019-01-14-4-5CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory01/18/2019Brian
Yes
01/25/2019necking okay
2019-01-14-4-6CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory01/18/2019Brian
Yes
01/25/2019necking okay

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2019-01-14-4-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-01-14-4-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-01-14-4-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-01-14-4-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-01-14-4-5 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-01-14-4-6 CTM 670-December 2013 (Verified)