Summary for Test 2018-12-13-1-3
Test performed: ASTM B499-14Project Information
| Project Identifiers | DEA: No Project |
|---|---|
| DIST-CO-RTE-PM | --- |
| Award Date | Not set |
| Closeout Date | 11/01/2022 |
| Work Description | Special project identifier for material not associated with a project |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 12/13/2018 | Sample Unique Key | 1 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 12/21/2018 | Sample type | Stock |
| A brief description of the sample | 3/4-10 x 18" | The quantity of what the sample constitutes | 50 |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Arthur |
| Last name of sampler or witnessed by | Peterson | Title of sampler | CALTRANS QA INSPECTOR |
| Telephone number of sampler | 707-342-8602 | Laboratory sample identification | Unknown |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | Blue Circle Corp |
| Transportation Laboratory (TL) Number | Unknown | Inspector Lot Number from the Transportation Laboratory (TL) Form | L110 124-18 |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | n/a |
|---|---|---|---|
| Heat Number(s) | 428917 | Nut Mfg. Lot Number(s) | n/a |
| Washer Mfg. Lot Number(s) | n/a | Bolt Specification | ASTM F1554 Grade 55 |
| Bolt Length(s) | 18" | Nut Specification | n/a |
| Washer Specification | n/a | Finish | hot dip galvanized |
| Diameter/Size | 3/4-10 | Bolt Mfg. Lot Number | n/a |
| Rocap Test Requirement(s) | n | Lubricant Requirements(s) | none |
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2018-12-13-1
DIME Test ID: 2018-12-13-1-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2019-01-02
Test Results
Input Type: Calculated
Tester's full name: Fred Saylor
Date of test: 12/26/2018
Sample No.: 1A
Rocap Number: no data
Heat Number(s): 428917
Mfg. Lot Number: no data
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: YELLOW PAINT
Size: .75 in
Bolt Length: 18 in
Measurement Average: 4.35 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/26/2018 ✔