Summary for Test 2018-12-13-3-3

Test performed: ASTM D412-06a-re13

Project Information

Project Identifiers
DEA: No Project
DIST-CO-RTE-PM---
Award DateNot set
Closeout Date11/01/2022
Work DescriptionSpecial project identifier for material not associated with a project
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date12/13/2018 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/17/2018
Sample typeQuality Assurance A brief description of the sampleJoint Seal
The quantity of what the sample constitutes550 ft From where was the sample collectedManufacturer
First name of sampler or witnessed byDavid Last name of sampler or witnessed bySimon
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameWatson Bowman Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM2 - Type B Elastomeric Joint Seal Mfg. Lot Number(s)3918437
Manufacturer(s)Watson Bowman Temperature72
Humidity50 CommentsUnknown
Joint Seal Size3.75

Test Details

DIME Sample ID: 2018-12-13-3
DIME Test ID: 2018-12-13-3-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Test Release Date: 2019-01-15

Test Results


Number of specimens tested: 3
Unit of the Ultimate Tensile Values: psi
Input Type: Calculated
Tester's full name: Steve
Date of test: 12/20/2018
UTM: 2KIP
Humidity: 50 %
Temperature: 72 F
Sample 1 Median Thickness: 0.051 in
Sample 1 Thickness all Within 0.003 inch?: Yes
Sample 1 Ultimate Tensile: 2187.5 lbf?in/in?
Sample 1 Elongation (350% Min): Pass
Sample 2 Median Thickness: 0.057 in
Sample 2 Thickness all Within 0.003 inch?: Yes
Sample 2 Ultimate Tensile: 2307.7 lbf?in/in?
Sample 2 Elongation (350% Min): Pass
Sample 3 Median Thickness: 0.055 in
Sample 3 Thickness all Within 0.003 inch?: Yes
Sample 3 Ultimate Tensile: 2318.8 lbf?in/in?
Sample 3 Elongation (350% Min): Pass
Median of the Ultimate Tensile Values: 2307.7 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point File
Test graph for Sample 1

Source: Partner Data Point File
Test graph for Sample 2

Source: Partner Data Point File
Test graph for Sample 3

Test was verified on 1/8/2019