Summary for Test 2018-11-28-9-5

Test performed: CTM 229-June 2011

Project Information

Project IdentifiersProject ID: 88888
DEA: SMTL-STOCK
EFIS: SMTL-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date11/28/2018 Sample Unique Key9
Date that the sample was received by the laboratory/organization performing the testing12/04/2018 Sample typePer Request
A brief description of the samplecombine 1/2 and 3/8 coarse agg. The quantity of what the sample constitutescombined 1/2 and 3/8 coarse agg at lab
From where was the sample collectedManufacturer First name of sampler or witnessed byE
Last name of sampler or witnessed byYip Title of samplerMets Rep
Telephone number of samplerUnknown Laboratory sample identification18-0137
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameCoalinga
Transportation Laboratory (TL) NumberC724452 Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-10-0006
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedSierra Pacific Materials Avenal
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1/2 inch
The concrete mix design numberUnknown Lot numberNot set
Sublot numberNot set Aggregate Mix NumberNot set
HMA PayNo

Test Details

DIME Sample ID: 2018-11-28-9
DIME Test ID: 2018-11-28-9-5
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: CTM 229-June 2011: Method of Test for Durability Index
Test Release Date: 2018-12-20

Test Results


What test(s) are being run?: Coarse durability only
Input Type: Calculated
Tester's full name: Bang Nguyen
Date of test: 12/20/2018
Coarse durability index: 76
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/20/2018