Sample Record

Owner Lab

  • CT HQ - Sacramento Aggregate Testing Laboratory

DIME Sample ID 2018-11-28-9

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 88888
DEA: SMTL-STOCK
EFIS: SMTL-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date11/28/2018 Sample Unique Key9
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/04/2018
Sample typePer Request A brief description of the samplecombine 1/2 and 3/8 coarse agg.
The quantity of what the sample constitutescombined 1/2 and 3/8 coarse agg at lab From where was the sample collectedManufacturer
First name of sampler or witnessed byE Last name of sampler or witnessed byYip
Title of samplerMets Rep Telephone number of samplerUnknown
Laboratory sample identification18-0137 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameCoalinga Transportation Laboratory (TL) NumberC724452
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-10-0006
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedSierra Pacific Materials Avenal
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1/2 inch
The concrete mix design numberUnknown Lot numberNot set
Sublot numberNot set Aggregate Mix NumberNot set
HMA PayNo

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2018-11-28-9-1AGGLP SIEVE_ANALYSIS-1: Soils for Corrosion Sieve AnalysisBang Nguyen, CT HQ - Sacramento Aggregate Testing Laboratory12/20/2018Bang Nguyen
Yes
12/20/2018
2018-11-28-9-2AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)Bang Nguyen, CT HQ - Sacramento Aggregate Testing Laboratory12/20/2018Bang Nguyen
Yes
12/20/2018
2018-11-28-9-3AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)Bang Nguyen, CT HQ - Sacramento Aggregate Testing Laboratory12/20/2018Bang Nguyen
Yes
12/20/2018
2018-11-28-9-4CTM 227-December 2014: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness)Bang Nguyen, CT HQ - Sacramento Aggregate Testing Laboratory12/20/2018Bang Nguyen
Yes
12/20/2018
2018-11-28-9-5CTM 229-June 2011: Method of Test for Durability IndexBang Nguyen, CT HQ - Sacramento Aggregate Testing Laboratory12/20/2018Bang Nguyen
Yes
12/20/2018
2018-11-28-9-6ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)Bang Nguyen, CT HQ - Sacramento Aggregate Testing Laboratory12/20/2018Bang Nguyen
Yes
12/20/2018
2018-11-28-9-7CTM 214-August 2010: Method of Test for Soundness of Aggregates by Use of Sodium SulfateBang Nguyen, CT HQ - Sacramento Aggregate Testing Laboratory12/20/2018Bang Nguyen
Yes
12/20/2018

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2018-11-28-9-1 AGGLP SIEVE_ANALYSIS-1 (Verified)
DIME Test ID: 2018-11-28-9-2 AASHTO T335-09r13 (Verified)
DIME Test ID: 2018-11-28-9-3 AASHTO T96-02r10 (Verified)
DIME Test ID: 2018-11-28-9-4 CTM 227-December 2014 (Verified)
DIME Test ID: 2018-11-28-9-5 CTM 229-June 2011 (Verified)
DIME Test ID: 2018-11-28-9-6 ASTM D4791-10 (Verified)
DIME Test ID: 2018-11-28-9-7 CTM 214-August 2010 (Verified)