Summary for Test 2018-12-07-1-1
Test performed: ASTM F606-14Project Information
| Project Identifiers | DEA: No Project |
|---|---|
| DIST-CO-RTE-PM | --- |
| Award Date | Not set |
| Closeout Date | 11/01/2022 |
| Work Description | Special project identifier for material not associated with a project |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 12/07/2018 | Sample Unique Key | 1 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/13/2018 |
| Sample type | Verification | A brief description of the sample | .75" x 15" anchor bolts |
| The quantity of what the sample constitutes | 49 | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Ken | Last name of sampler or witnessed by | Varela |
| Title of sampler | Associate Steel Inspector | Telephone number of sampler | 5624407716 |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | A and M Nut and Bolt | Transportation Laboratory (TL) Number | Unknown |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L08-084-18 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | N/A |
|---|---|---|---|
| Heat Number(s) | 58034809-08 | Nut Mfg. Lot Number(s) | 22144-6213825703 |
| Washer Mfg. Lot Number(s) | 304172 | Bolt Specification | ASTM F1554 Gr. 55 |
| Bolt Length(s) | 15" | Nut Specification | ASTM A563 |
| Washer Specification | ASTMF436 | Finish | HDG |
| Diameter/Size | 0.75" | Bolt Mfg. Lot Number | 44395-PPO |
| Rocap Test Requirement(s) | None | Lubricant Requirements(s) | None |
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2018-12-07-1
DIME Test ID: 2018-12-07-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2018-12-25
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 12/14/2018
UTM: 400KIP
Temperature: 72
| Num | Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments |
|---|---|---|---|---|---|---|---|---|---|
| 1 | 1A | F1554 Rod Axial | 0.334 | 28886 | 128 | 86485 | 63076 | 21067 | F1554 Rod |
General comments (publicly viewable) (Max 1000 characters): F1554 Rod
Test Graph
Source: Partner Data Point FileTest was verified on 12/18/2018 ✔