Summary for Test 2018-11-20-5-1
Test performed: ASTM F606-14aProject Information
| Project Identifiers | DEA: No Project |
|---|---|
| DIST-CO-RTE-PM | --- |
| Award Date | Not set |
| Closeout Date | 11/01/2022 |
| Work Description | Special project identifier for material not associated with a project |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 11/20/2018 | Sample Unique Key | 5 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 12/05/2018 | Sample type | Verification |
| A brief description of the sample | F1554 Grade 55 HDG Anchor Bolts | The quantity of what the sample constitutes | 120 |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Ken |
| Last name of sampler or witnessed by | Varela | Title of sampler | Associate Steel Inspector |
| Telephone number of sampler | (562) 440-7716 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | AandM Nut and Bolt | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | L08-077-18 | |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | N/A |
|---|---|---|---|
| Heat Number(s) | 58032928 | Nut Mfg. Lot Number(s) | 401824A |
| Washer Mfg. Lot Number(s) | 308773 | Bolt Specification | ASTM F1554-15 Gr 55 |
| Bolt Length(s) | 36" | Nut Specification | ASTM A194 Gr 2H |
| Washer Specification | ASTM F436 | Finish | HDG |
| Diameter/Size | 1" | Bolt Mfg. Lot Number | 44159-PPO |
| Rocap Test Requirement(s) | None | Lubricant Requirements(s) | |
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2018-11-20-5
DIME Test ID: 2018-11-20-5-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2018-12-14
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 12/05/2018
UTM: 400KIP
Temperature: 72 F
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 1A | 401824A | 1-8 HEX | 107650 | 478.83 | Nut Proof | Brian |
General comments (publicly viewable) (Max 1000 characters): Nut Proof
Test Graph
Source: Partner Data Point FileTest was verified on 12/7/2018 ✔