Summary for Test 2018-05-14-7-12
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | DEA: No Project |
|---|---|
| DIST-CO-RTE-PM | --- |
| Award Date | Not set |
| Closeout Date | 11/01/2022 |
| Work Description | Special project identifier for material not associated with a project |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 05/14/2018 | Sample Unique Key | 7 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/14/2018 |
| Sample type | Department Acceptance | A brief description of the sample | Erico Position Coupler |
| The quantity of what the sample constitutes | 8 | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Anirudha | Last name of sampler or witnessed by | Vaidya |
| Title of sampler | Unknown | Telephone number of sampler | Unknown |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Nucor Erico | Transportation Laboratory (TL) Number | NA |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | NA | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Authorization Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Manufacturer | Nucor |
| Coupler Manufacturer | Erico | Intermediate Assembler or Fabricator | Unknown |
| Rebar Size | 8 | Coupler Model | Position Coupler |
| Coating Standards | Uncoated | Shape of Rebar | Straight |
| Rebar Hoop Diameter | Unknown | Rebar Hoop Fabricator | Unknown |
| Coupler Component Heat/Lot Number(s) | LA-834, LA-873, LA-905, LA-870 | Rebar Heat Number(s) | SE16103928, SE16104013 |
| Rebar Size 2 | 11 | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2018-05-14-7
DIME Test ID: 2018-05-14-7-12
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2019-01-25
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 11/27/2018
UTM: 2000KIP
Halo ID: Big
Temperature: 72 F
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|---|
| 1 | 3 | A18 | #18/57mm | 4 | -0.0014 | 387264 | 96816 | necking okay | Brian |
General comments (publicly viewable) (Max 1000 characters): necking okay
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 1/18/2019 ✔