Summary for Test 2018-09-26-4-2
Test performed: ASTM F606-14Project Information
| Project Identifiers | DEA: No Project |
|---|---|
| DIST-CO-RTE-PM | --- |
| Award Date | Not set |
| Closeout Date | 11/01/2022 |
| Work Description | Special project identifier for material not associated with a project |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 09/26/2018 | Sample Unique Key | 4 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 10/03/2018 | Sample type | Quality Assurance |
| A brief description of the sample | F1554 Grade 55 HDG Anchor Bolts | The quantity of what the sample constitutes | 8 |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | William |
| Last name of sampler or witnessed by | Clifford | Title of sampler | QA Inspector |
| Telephone number of sampler | (510) 325-3065 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | AM Nut and Bolt | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | L78-051-18 | |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | 3048578 | Nut Mfg. Lot Number(s) | 100786214 |
| Washer Mfg. Lot Number(s) | 21518850 | Bolt Specification | F1554 |
| Bolt Length(s) | 10 1/2" | Nut Specification | A563 |
| Washer Specification | F436 | Finish | HDG |
| Diameter/Size | 1/2" | Bolt Mfg. Lot Number | 3048578 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2018-09-26-4
DIME Test ID: 2018-09-26-4-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2018-10-12
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 10/04/2018
UTM: 400KIP
Temperature: 72
| Num | Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments |
|---|---|---|---|---|---|---|---|---|---|
| 1 | 1A | Axial Pull .5 x 10\" x 4 F1554 Grade55 Anchor Bolt | 0.1419 | 11744 | 52 | 82763 | 57558 | 8168 | F1554 Axial Pull |
General comments (publicly viewable) (Max 1000 characters): F1554 Axial Pull
Test Graph
Source: Partner Data Point FileTest was verified on 10/5/2018 ✔