Summary for Test 2017-05-05-17-8
Test performed: AASHTO T304-11Project Information
Project Identifiers | DEA: No Project |
---|---|
DIST-CO-RTE-PM | --- |
Award Date | Not set |
Closeout Date | 11/01/2022 |
Work Description | Special project identifier for material not associated with a project |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 05/05/2017 | Sample Unique Key | 17 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/05/2017 |
Sample type | Verification | A brief description of the sample | Sized, Untreated, Virgin Aggregates |
The quantity of what the sample constitutes | JMF Verification | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Joseph | Last name of sampler or witnessed by | Sturges |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | D76918 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Shasta Ranch Aggregates | Transportation Laboratory (TL) Number | 851339 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | JMF 17-04-S1 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-45-0057::SHASTA RANCH AGGREGATES |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | Unknown | A detailed description of where the material sample was collected | Lab-Batched from Sized Untreated Aggregate Stockpiles |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 3/4 inch |
The concrete mix design number | JMF 17-04-S1 | Lot number | Not set |
Sublot number | Not set | Aggregate Mix Number | Not set |
HMA Pay | No |
Test Details
DIME Sample ID: 2017-05-05-17
DIME Test ID: 2017-05-05-17-8
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Test Release Date: 2018-09-27
Test Results
What test method is performed?: Method A
Input Type: Calculated
Tester's full name: Mike Cruz
Date of test: 05/24/2017
Bulk dry specific gravity: 2.622
Average uncompacted voids: 47.2 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/27/2018 ✔