Summary for Test 2018-08-14-16-24
Test performed: ASTM E18-15Project Information
Project Identifiers | DEA: No Project |
---|---|
DIST-CO-RTE-PM | --- |
Award Date | Not set |
Closeout Date | 11/01/2022 |
Work Description | Special project identifier for material not associated with a project |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 08/14/2018 | Sample Unique Key | 16 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/27/2018 |
Sample type | Quality Assurance | A brief description of the sample | KT A325 Bolts |
The quantity of what the sample constitutes | 10 | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Jason | Last name of sampler or witnessed by | Williams |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Ameron | Transportation Laboratory (TL) Number | NA |
Inspector Lot Number from the Transportation Laboratory (TL) Form | NA | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | NA |
---|---|---|---|
Heat Number(s) | 3077646 | Nut Mfg. Lot Number(s) | NA |
Washer Mfg. Lot Number(s) | NA | Bolt Specification | A325, F3125 |
Bolt Length(s) | 4.5, 4.0 | Nut Specification | NA |
Washer Specification | NA | Finish | F2329 HDG |
Diameter/Size | 1.5 | Bolt Mfg. Lot Number | 51776-1, 51776-2 |
Rocap Test Requirement(s) | NA | Lubricant Requirements(s) | NA |
Test Details
DIME Sample ID: 2018-08-14-16
DIME Test ID: 2018-08-14-16-24
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Test Release Date: 2018-09-11
Test Results
Input Type: Calculated
Tester's full name: Fred Saylor
Date of test: 08/31/2018
Sample No.: 2A
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: 51776-1
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: KT A325
Size: 1.5 in
Bolt Length: 4.5 in
Hardness Reading Scale: C Scale
Spacing: Ok
Hardness Reading Average: 23.67
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/4/2018 ✔