Summary for Test 2018-08-10-1-25
Test performed: ASTM F606-14aProject Information
| Project Identifiers | DEA: No Project |
|---|---|
| DIST-CO-RTE-PM | --- |
| Award Date | Not set |
| Closeout Date | 11/01/2022 |
| Work Description | Special project identifier for material not associated with a project |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 08/10/2018 | Sample Unique Key | 1 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/14/2018 | Sample type | Quality Assurance |
| A brief description of the sample | F1554 Grade 55 HDG Anchor Bolts | The quantity of what the sample constitutes | 3 |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Kevin |
| Last name of sampler or witnessed by | Churchill | Title of sampler | QA Inspector |
| Telephone number of sampler | 510-693-3545 | Laboratory sample identification | Unknown |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | AandM Nut and Bolt |
| Transportation Laboratory (TL) Number | Unknown | Inspector Lot Number from the Transportation Laboratory (TL) Form | L02-051-18 |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | 3078714 | Nut Mfg. Lot Number(s) | 28220 |
| Washer Mfg. Lot Number(s) | 308773 | Bolt Specification | F1554 |
| Bolt Length(s) | 36" | Nut Specification | A194 Gr 2H |
| Washer Specification | F436 | Finish | HDG |
| Diameter/Size | 1" | Bolt Mfg. Lot Number | 43163-PPO |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | Blue Dye | |
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2018-08-10-1
DIME Test ID: 2018-08-10-1-25
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2018-09-04
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 08/23/2018
UTM: 400KIP
Temperature: 72 F
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 1A | 28220-6214582402 | 1-8 HEX | 108950 | 484.65 | Nut Proof | Brian |
General comments (publicly viewable) (Max 1000 characters): Nut Proof
Test Graph
Source: Partner Data Point FileTest was verified on 8/28/2018 ✔