Summary for Test 2018-07-31-5-2
Test performed: ASTM F606-14aProject Information
| Project Identifiers | DEA: No Project |
|---|---|
| DIST-CO-RTE-PM | --- |
| Award Date | Not set |
| Closeout Date | 11/01/2022 |
| Work Description | Special project identifier for material not associated with a project |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 07/31/2018 | Sample Unique Key | 5 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/02/2018 | Sample type | Verification |
| A brief description of the sample | A325 bolt, all thread chisel point | The quantity of what the sample constitutes | 12 bolts 1 all thread |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | David |
| Last name of sampler or witnessed by | Flygare | Title of sampler | CA METS QA Inspector |
| Telephone number of sampler | 801-669-2984 | Laboratory sample identification | Unknown |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | UIS |
| Transportation Laboratory (TL) Number | Unknown | Inspector Lot Number from the Transportation Laboratory (TL) Form | B76-149-18 |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | none |
|---|---|---|---|
| Heat Number(s) | 100788102, 3052580 | Nut Mfg. Lot Number(s) | none |
| Washer Mfg. Lot Number(s) | none | Bolt Specification | A325, F1554 Gr.36 ,55 |
| Bolt Length(s) | 5 1/2", 11" | Nut Specification | none |
| Washer Specification | none | Finish | HDG |
| Diameter/Size | 3/4" x 5 1/2", 7/8" x 11" | Bolt Mfg. Lot Number | SLSB, Platt |
| Rocap Test Requirement(s) | none | Lubricant Requirements(s) | none |
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2018-07-31-5
DIME Test ID: 2018-07-31-5-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2018-08-16
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 08/09/2018
UTM: 400KIP
Temperature: no data
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1B | 100788102 | 3/4\" | 49496 | 220.2 | 10 | A325 | Brian |
General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point FileTest was verified on 8/9/2018 ✔