Summary for Test 2018-07-19-14-29
Test performed: ASTM E18-15Project Information
| Project Identifiers | DEA: No Project |
|---|---|
| DIST-CO-RTE-PM | --- |
| Award Date | Not set |
| Closeout Date | 11/01/2022 |
| Work Description | Special project identifier for material not associated with a project |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 07/19/2018 | Sample Unique Key | 14 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/19/2018 | Sample type | Quality Assurance |
| A brief description of the sample | 2, 2-1/4 A563 nuts | The quantity of what the sample constitutes | 5 from each lot |
| From where was the sample collected | Distributor | First name of sampler or witnessed by | Prescott |
| Last name of sampler or witnessed by | Leavitt | Title of sampler | QA Inspector |
| Telephone number of sampler | 5105900116 | Laboratory sample identification | Unknown |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | Universal Industrial Sales Dyson |
| Transportation Laboratory (TL) Number | Unknown | Inspector Lot Number from the Transportation Laboratory (TL) Form | S28-193-18 |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | N/A |
|---|---|---|---|
| Heat Number(s) | 188194, 166581, 188539 | Nut Mfg. Lot Number(s) | DDYO, DDWH, DDYZ |
| Washer Mfg. Lot Number(s) | N/A | Bolt Specification | N/A |
| Bolt Length(s) | N/A | Nut Specification | A563-DH |
| Washer Specification | N/A | Finish | Plain, Plain, HDG |
| Diameter/Size | 2, 2-1/4, 2-1/4 | Bolt Mfg. Lot Number | N/A |
| Rocap Test Requirement(s) | No | Lubricant Requirements(s) | No, No, Yes |
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2018-07-19-14
DIME Test ID: 2018-07-19-14-29
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Test Release Date: 2018-08-13
Test Results
Input Type: Calculated
Tester's full name: Brian Ewing
Date of test: 07/30/2018
Sample No.: 3C
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: DDYZ
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: 2H DH D/N
Size: 2.25 in
Bolt Length: no data
Hardness Reading Scale: C Scale
Spacing: Ok
Hardness Reading Average: 28.43
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/6/2018 ✔