Summary for Test 2018-07-18-1-22

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 212687
DEA: 06442544
EFIS: 0612000175
DIST-CO-RTE-PM06-KER-46,5-31.5-33.2
Award Date01/11/2018
Closeout Date11/19/2021
Work DescriptionCONVERT 2-LANE TO 4-LANE CONVENTIONAL HIGHWAY.
Location DescriptionKERN COUNTY NEAR LOST HILLS FROM 1.0 MILE EAST OF LOST HILLS ROAD TO 0.7 MILE EAST OF ROUTE 46/5 SEPARATION
QA Service Level1 (Verified on 03/12/2018)

Sample Information

Sample Taken Date07/18/2018 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/18/2018
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutes3276 From where was the sample collectedFabricator
First name of sampler or witnessed byTory Last name of sampler or witnessed byMcLaurin
Title of samplerQuality Assurance Inspector Telephone number of sampler6616185971
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameTNT Rebar Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormL67-068-18 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)65031329
Hoop Manufacturer Lot Number(s)1, 6, 11, 16, 21, 22 Material Standard CodeASTM A706
Material Grade60 Rebar Size5
Diameter of Hoop1'-4" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerGerdau
Welding CompanyTNT Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2018-07-18-1
DIME Test ID: 2018-07-18-1-22
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2018-08-01

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 07/24/2018
UTM: 75KIP
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
1122#5/16mm0.312998296720Bar Broke in Heat Affected ZoneFred

General comments (publicly viewable) (Max 1000 characters): Bar Broke in Heat Affected Zone; No Necking
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 7/25/2018