Sample Record
Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2018-07-18-1
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 212687 DEA: 06442544 EFIS: 0612000175 |
---|---|
DIST-CO-RTE-PM | 06-KER-46,5-31.5-33.2 |
Award Date | 01/11/2018 |
Closeout Date | 11/19/2021 |
Work Description | CONVERT 2-LANE TO 4-LANE CONVENTIONAL HIGHWAY. |
Location Description | KERN COUNTY NEAR LOST HILLS FROM 1.0 MILE EAST OF LOST HILLS ROAD TO 0.7 MILE EAST OF ROUTE 46/5 SEPARATION |
QA Service Level | 1 (Verified on 03/12/2018) |
Sample Information
Sample Taken Date | 07/18/2018 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/18/2018 |
Sample type | Quality Assurance | A brief description of the sample | Flash Welded Rebar Hoops |
The quantity of what the sample constitutes | 3276 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Tory | Last name of sampler or witnessed by | McLaurin |
Title of sampler | Quality Assurance Inspector | Telephone number of sampler | 6616185971 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | TNT Rebar | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L67-068-18 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Rebar Heat Number(s) | 65031329 |
Hoop Manufacturer Lot Number(s) | 1, 6, 11, 16, 21, 22 | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | 5 |
Diameter of Hoop | 1'-4" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | Gerdau |
Welding Company | TNT Rebar | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2018-07-18-1-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-07-18-1-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-07-18-1-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-07-18-1-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-07-18-1-5 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-07-18-1-6 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-07-18-1-7 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-07-18-1-8 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-07-18-1-9 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-07-18-1-10 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-07-18-1-11 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-07-18-1-12 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-07-18-1-13 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-07-18-1-14 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-07-18-1-15 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-07-18-1-16 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-07-18-1-17 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-07-18-1-18 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-07-18-1-19 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-07-18-1-20 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-07-18-1-21 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-07-18-1-22 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-07-18-1-23 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-07-18-1-24 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-07-18-1-25 CTM 670-December 2013 (Verified)