Summary for Test 2018-06-26-16-6
Test performed: ASTM D2628-91-re11-highProject Information
| Project Identifiers | DEA: No Project |
|---|---|
| DIST-CO-RTE-PM | --- |
| Award Date | Not set |
| Closeout Date | 11/01/2022 |
| Work Description | Special project identifier for material not associated with a project |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 06/26/2018 | Sample Unique Key | 16 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 06/27/2018 | Sample type | Quality Assurance |
| A brief description of the sample | 3.75 elastic joint seal | The quantity of what the sample constitutes | 550 ft |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Paula |
| Last name of sampler or witnessed by | Wilcox | Title of sampler | Unknown |
| Telephone number of sampler | Unknown | Laboratory sample identification | Unknown |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | Watson Bowman Joint Seal |
| Transportation Laboratory (TL) Number | Unknown | Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM2 - Type B Elastomeric Joint Seal | Mfg. Lot Number(s) | 1218265 |
|---|---|---|---|
| Manufacturer(s) | O BASF | Temperature | 74 |
| Humidity | 44 | Comments | Unknown |
| Joint Seal Size | 3.75" |
Test Details
DIME Sample ID: 2018-06-26-16
DIME Test ID: 2018-06-26-16-6
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM D2628-91-re11-high: Standard Specification for Preformed Polychloroprene Elastomeric Joint Seals for Concrete Pavements (High Temp Recovery)
Test Release Date: 2018-07-20
Test Results
Input Type: Measured
Tester's full name: Brian Ewing
Date of test: 07/06/2018
Temperature: 72 f
Humidity: 50 %
High Temp Recovery (70 hrs at 212F) Size Before (Height of Contact Face ): 3.75 in
High Temp Recovery (70 hrs at 212F) Size After (Expanded Contact Face ): 3.643 in
Percent Recovery (High Temp): 97 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/13/2018 ✔