Summary for Test 2018-06-30-8-1
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 212741 DEA: 020E1804 EFIS: 0200000022 |
---|---|
DIST-CO-RTE-PM | 02-PLU-89-29.8/30.2 |
Award Date | 12/13/2017 |
Closeout Date | 12/17/2021 |
Work Description | BRIDGE REPLACEMENT |
Location Description | PLUMAS COUNTY NEAR CANYON DAM FROM 0.2 MILE SOUTH TO 0.3 MILE NORTH OF LAKE ALMANOR SPILLWAY |
QA Service Level | 1 (Verified on 12/06/2017) |
Sample Information
Sample Taken Date | 06/30/2018 | Sample Unique Key | 8 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/02/2018 |
Sample type | Quality Assurance | A brief description of the sample | Couplers |
The quantity of what the sample constitutes | 8 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Brian | Last name of sampler or witnessed by | Holck |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Confab HRC | Transportation Laboratory (TL) Number | C931426 C931428 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S44-016-18, S44-018-18 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Manufacturer | CMC |
Coupler Manufacturer | HRC | Intermediate Assembler or Fabricator | Confab HRC |
Rebar Size | 10 | Coupler Model | HRC 500 510 |
Coating Standards | Uncoated | Shape of Rebar | Straight |
Rebar Hoop Diameter | Unknown | Rebar Hoop Fabricator | Unknown |
Coupler Component Heat/Lot Number(s) | 75070365, 75069694 | Rebar Heat Number(s) | 4073764 |
Rebar Size 2 | Not set | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2018-06-30-8
DIME Test ID: 2018-06-30-8-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2018-07-10
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 07/02/2018
UTM: 2000KIP
Halo ID: Big
Temperature: 72 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|
1 | 1 | 1 | #10/32mm | 1.27 | -0.0021 | 118342 | 93183 | necking okay | Brian |
General comments (publicly viewable) (Max 1000 characters): necking okay
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 7/3/2018 ✔