Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2018-06-30-8

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 212741
DEA: 020E1804
EFIS: 0200000022
DIST-CO-RTE-PM02-PLU-89-29.8/30.2
Award Date12/13/2017
Closeout Date12/17/2021
Work DescriptionBRIDGE REPLACEMENT
Location DescriptionPLUMAS COUNTY NEAR CANYON DAM FROM 0.2 MILE SOUTH TO 0.3 MILE NORTH OF LAKE ALMANOR SPILLWAY
QA Service Level1 (Verified on 12/06/2017)

Sample Information

Sample Taken Date06/30/2018 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/02/2018
Sample typeQuality Assurance A brief description of the sample Couplers
The quantity of what the sample constitutes8 From where was the sample collectedManufacturer
First name of sampler or witnessed byBrian Last name of sampler or witnessed byHolck
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameConfab HRC Transportation Laboratory (TL) NumberC931426 C931428
Inspector Lot Number from the Transportation Laboratory (TL) FormS44-016-18, S44-018-18 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC
Coupler ManufacturerHRC Intermediate Assembler or FabricatorConfab HRC
Rebar Size10 Coupler ModelHRC 500 510
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)75070365, 75069694 Rebar Heat Number(s)4073764
Rebar Size 2 Not set Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2018-06-30-8-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory07/02/2018Brian
Yes
07/10/2018necking okay
2018-06-30-8-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory07/02/2018Brian
Yes
07/10/2018necking okay
2018-06-30-8-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory07/02/2018Brian
Yes
07/10/2018necking okay
2018-06-30-8-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory07/02/2018Brian
Yes
07/10/2018necking okay
2018-06-30-8-5CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory07/02/2018Brian
Yes
07/10/2018necking okay
2018-06-30-8-6CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory07/02/2018Brian
Yes
07/10/2018necking okay

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2018-06-30-8-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-06-30-8-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-06-30-8-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-06-30-8-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-06-30-8-5 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-06-30-8-6 CTM 670-December 2013 (Verified)