Summary for Test 2018-06-19-1-4
Test performed: ASTM F606-14aProject Information
| Project Identifiers | DEA: No Project |
|---|---|
| DIST-CO-RTE-PM | --- |
| Award Date | Not set |
| Closeout Date | 11/01/2022 |
| Work Description | Special project identifier for material not associated with a project |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 06/19/2018 | Sample Unique Key | 1 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/26/2018 |
| Sample type | Department Acceptance | A brief description of the sample | 1 x 40 anchor bolts |
| The quantity of what the sample constitutes | 243 | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Ken | Last name of sampler or witnessed by | Varela |
| Title of sampler | Associate Steel Inspector | Telephone number of sampler | 5624407716 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | A and M Nut and Bolt | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | N/A |
|---|---|---|---|
| Heat Number(s) | 10089176 | Nut Mfg. Lot Number(s) | 28220-75070239 |
| Washer Mfg. Lot Number(s) | 307240 | Bolt Specification | ASTM F1554 Gr. 105 |
| Bolt Length(s) | 40 inch | Nut Specification | ASTM A194 2H |
| Washer Specification | ASTM F436 | Finish | HDG |
| Diameter/Size | 1 inch | Bolt Mfg. Lot Number | 42607-PPO |
| Rocap Test Requirement(s) | None | Lubricant Requirements(s) | None |
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2018-06-19-1
DIME Test ID: 2018-06-19-1-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2018-07-10
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 06/28/2018
UTM: 400KIP
Temperature: 72 F
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 1B | 28220-75070239 | 1\" | 93101 | 414.13 | Proof Load | Fred |
General comments (publicly viewable) (Max 1000 characters): Proof Load
Test Graph
Source: Partner Data Point FileTest was verified on 7/3/2018 ✔